Flat cable FE180/E90 3G6 OR

Flat cable FE180/E90 3G6 OR

Article number: 48550OR
Price on demand
Flat cable Woertz FE180/E30/E90 3x6.00mm 2 FR/LS0H orange LNPE (rodent repellent)Fire protection cable with non-critical behavior (according to VKF guideline 14-15) for use in horizontal and vertical escape routes. Suitable for use in public buildings and facilities such as hospitals, hotels, offices, museums or other commercial buildings (KBOB). Also recommended for facilities with an increasing number of people in increasingly confined spaces such as airports, railroad stations (above and below ground) or shopping centers (KBOB). Within the Woertz fire protection cabling systems, also ideally suited for the high demands of infrastructure buildings such as tunnels, underpasses, parking garages or subway stations.
Base Unit Meter
availability Delivery in 4 weeks
Weight (g) 350 g
Construction (mm²) 3x6 mm²
Halogen free Yes
International designation N1ZZ1H2-U
Reaction to fire classification B2ca s1a d0 a1
Fire behavior Cables with non-critical behavior (according to VKF 14-15)
Sheath color Orange
Rodent protection rodent repellent
Tender text
Flat cable FE180/E90 3G6 OR (48550OR): Woertz flat cable FE180/E30/E90 3x6.0mm² FR/LSOH orange LNPE. (rodent repellent) Reaction to fire classification: B2ca s1a d0 a1
Copy
Files
Declaration of Conformity
Characteristics
Base Unit Meter
availability Delivery in 4 weeks
group 170000
Packaging unit -
country of origin CH
Customs tariff number 8544.4992
Weight (g) 350 g
Copper weight (g) 116 g
Technical data
Construction (mm²) 3x6 mm²
Halogen free Yes
Cable type Fire safety flat cable
International designation N1ZZ1H2-U
Reaction to fire classification B2ca s1a d0 a1
Fire behavior Cables with non-critical behavior (according to VKF 14-15)
Cross section (mm²) 4 mm²
Copper conductor Wire KL1 EN60228
Conductor resistance (ohm/km) 4,61 ohm/km
cores insulation Flame retardant, high temperature resistant
Cores colors brown,green/yellow,blue
Sheat insulation Polyolefin flame retardant
Sheath color Orange
Rodent protection rodent repellent
Longitudinal watertightness < 1 m/14 days EN60794-1-2-F5B
Operating Temperature -25 till 90 °C
Installation temperature min. 5 °C
Nominal voltage (VAC) 600/1000 VAC
Test voltage 4 kV/50Hz
Fire load (kWh/m) 0,91
Halogen free acc. to IEC/EN60754-1/2
Flame retardant according to IEC/EN60332-1-2
Minimal smoke emision acc. to IEC/EN 61034-2
Insulation integrity FE180 (IEC 60331) / PH120 (EN50200)

This product is a member of the following product systems

3011
Woertz fire safety system FE180 E30/E90 3G6 mm² for supplying power to safety-relevant elements such as emergency and escape route lighting, smoke extraction systems or fire department elevators.