Flat cable FE180/E90 3G6 OR
Article number: 48550OR
Price on demand
Flat cable Woertz FE180/E30/E90 3x6.00mm 2 FR/LS0H orange LNPE (rodent repellent)Fire protection cable with non-critical behavior (according to VKF guideline 14-15) for use in horizontal and vertical escape routes. Suitable for use in public buildings and facilities such as hospitals, hotels, offices, museums or other commercial buildings (KBOB). Also recommended for facilities with an increasing number of people in increasingly confined spaces such as airports, railroad stations (above and below ground) or shopping centers (KBOB). Within the Woertz fire protection cabling systems, also ideally suited for the high demands of infrastructure buildings such as tunnels, underpasses, parking garages or subway stations.
Base Unit | Meter |
availability | Delivery in 4 weeks |
Weight (g) | 350 g |
Construction (mm²) | 3x6 mm² |
Halogen free | Yes |
International designation | N1ZZ1H2-U |
Reaction to fire classification | B2ca s1a d0 a1 |
Fire behavior | Cables with non-critical behavior (according to VKF 14-15) |
Sheath color | Orange |
Rodent protection | rodent repellent |
Tender text
Flat cable FE180/E90 3G6 OR (48550OR): Woertz flat cable FE180/E30/E90 3x6.0mm² FR/LSOH orange LNPE. (rodent repellent) Reaction to fire classification: B2ca s1a d0 a1
Copy
Construction (mm²) | 3x6 mm² |
Halogen free | Yes |
Cable type | Fire safety flat cable |
International designation | N1ZZ1H2-U |
Reaction to fire classification | B2ca s1a d0 a1 |
Fire behavior | Cables with non-critical behavior (according to VKF 14-15) |
Cross section (mm²) | 4 mm² |
Copper conductor | Wire KL1 EN60228 |
Conductor resistance (ohm/km) | 4,61 ohm/km |
cores insulation | Flame retardant, high temperature resistant |
Cores colors | brown,green/yellow,blue |
Sheat insulation | Polyolefin flame retardant |
Sheath color | Orange |
Rodent protection | rodent repellent |
Longitudinal watertightness | < 1 m/14 days EN60794-1-2-F5B |
Operating Temperature | -25 till 90 °C |
Installation temperature min. | 5 °C |
Nominal voltage (VAC) | 600/1000 VAC |
Test voltage | 4 kV/50Hz |
Fire load (kWh/m) | 0,91 |
Halogen free acc. to | IEC/EN60754-1/2 |
Flame retardant according to | IEC/EN60332-1-2 |
Minimal smoke emision acc. to | IEC/EN 61034-2 |
Insulation integrity | FE180 (IEC 60331) / PH120 (EN50200) |
This product is a member of the following product systems
3011
Woertz fire safety system FE180 E30/E90 3G6 mm² for supplying power to safety-relevant elements such as emergency and escape route lighting, smoke extraction systems or fire department elevators.