End caps FC E90 3G2.5/3G4.0/3G6.0
Article number: 48961
Price on demand
End caps E90 IP66/68 for flat cable FE180 E90 3G2.5mm 2 /3G4.0mm 2 /3G6.0mm 2
Tender text
End caps FC E90 3G2.5/3G4.0/3G6.0 (48961):
Copy
Dimensions length x width x height (mm) | 30x28.6x23.5 mm |
Dimensions length x width x height (inch) | 1.18x1.12x0.92 inch |
Degree of protection | IP66/IP68 (2m,30min) |
Metal parts | Corrosion protected |
Number of poles | 3 pole |
Contacting type | Screw terminal |
Connection conductor (mm²) | 3x2.5 mm² |
Connecting capacity (mm) | 4.5 mm |
Rated current heavy current part (A) | 41 (6 mm²) A |
Fire behavior | V0 (UL94) |
Operating Temperature (°C) | -15 to 85 °C |
Installation temperature min. (°C) | 5 °C |
Function maintenance | E30/E90 (DIN 4102-12) |
Plastic parts | Halogen-free |
Material housing | Ceramics |
Number Screwdriver Clamping screws Heavy current part | schraubklemmen |
Fire load (KWh) | 0,45 kWh |
Product accessories
Flat cable Woertz FE180/E30/E90 3x2.5 mm² FR/LS0H orange LNPE (rodent repellent) Fire protection cable with non-critical behavior (according to VKF guideline 14-15) for use in horizontal and vertical escape routes. Applicable in public buildings and facilities such as hospitals, hotels, offices, museums or other commercial buildings (KBOB). Also recommended for facilities with increasing numbers of people in increasingly confined spaces such as airports, train stations (above and below ground) or shopping malls (KBOB). Within the Woertz fire protection cabling systems also ideally suited for the high demands of infrastructure buildings such as tunnels, underpasses, parking garages or subway stations.
Article number | 48250OR |
Base Unit | Meter |
availability | Delivery in 4 weeks |
Weight (g) | 247 |
Construction (mm²) | 3x2.5 |
Halogen free | Yes |
International designation | N1ZZ1H2-U |
Reaction to fire classification | B2ca s1a d0 a1 |
Sheath color | Orange |
Rodent protection | rodent repellent |
Flat cable Woertz FE180/E30/E90 3x4.00mm 2 FR/LS0H orange LNPE (rodent repellent)Fire protection cable with non-critical behavior (according to VKF guideline 14-15) for use in horizontal and vertical escape routes. Applicable in public buildings and facilities such as hospitals, hotels, offices, museums or other commercial buildings (KBOB). Also recommended for facilities with an increasing number of people in ever tighter spaces such as airports, train stations (above and below ground) or shopping malls (KBOB). Within the Woertz fire protection cabling systems also ideally suited for the high demands of infrastructure buildings such as tunnels, underpasses, parking garages or subway stations.
Article number | 48450OR |
Base Unit | Meter |
availability | Delivery in 4 weeks |
Weight (g) | 330 |
Construction (mm²) | 3x4.0 |
Halogen free | Yes |
International designation | N1ZZ1H2-U |
Reaction to fire classification | B2ca s1a d0 a1 |
Sheath color | Orange |
Rodent protection | rodent repellent |
This product is a member of the following product systems
3000
Woertz Fire Safety System FE180 E30/E90 3G2.5 mm² for power supply of safety-relevant elements, such as emergency and escape route lighting, smoke extraction systems or fire department elevators.
3010
Woertz fire safety system FE180 E30/E90 3G4 mm² for power supply of safety-relevant elements, such as emergency and escape route lighting, smoke extraction systems or fire department elevators.